Shale Chem
Coiled-tubing coupons: untreated rings heavily rusted, inhibited rings clean, and treated vs untreated fluids.
Field Results/Coiled tubing · SCL 8054

Oxygen, salt, and a coiled string.

Overview

Seven-day corrosion-inhibition test under fully oxygenated conditions at 30–50°C in 2% KCl solution. SCL 8054 also proved effective in high-TDS Ca and Na brine drilling fluids, with compatibility across traditional inhibitors.

Chemistry
SCL 8054 (corrosion inhibitor)
Application
Coiled tubing
Location
Anonymized
Headline result
7 days · fully oxygenated test
From the bench
2% KCl untreated · with inhibitor · fluids after test (untreated & treated)
2% KCl untreated · with inhibitor · fluids after test (untreated & treated)

The corrosion inhibition performance of SCL 8054 was evaluated over a 7-day corrosion-inhibition test under fully oxygenated conditions at 30–50°C in a 2% KCl solution.

Beyond low-salinity systems, SCL 8054 also proved effective in high-TDS Ca and Na brine drilling fluids. Its compatibility with traditional inhibitors such as Imidazoline/Quat and Coco Quat further highlights its versatility.

Key testing points

  • The corrosion inhibition test for SCL 8054 chemistry was conducted over 7 days under fully oxygenated conditions with temperatures ranging from 30–50°C in a 2% KCl solution
  • SCL 8054 has shown efficacy in both low salinity and high TDS Ca and Na brine drilling fluids
  • Versatility with traditional corrosion inhibitors like Imidazoline/Quat and Coco Quat
Oxygenated Protection

Proven effective under 30–50°C with oxygen present.

Wide Salinity Range

Performs in both low and high TDS fluids.

Strong Compatibility

Works alongside traditional inhibitors.

Reliable Performance

Consistent results in demanding environments.

Frequently asked

What conditions was SCL 8054 tested under?
It was tested for 7 days under fully oxygenated conditions, at 30–50°C in a 2% KCl solution.
How effective is SCL 8054 in oxygenated environments?
The results showed strong corrosion protection, proving its reliability even in challenging oxygen-rich conditions.
Can SCL 8054 be used in high-salinity systems?
Yes. It has demonstrated excellent performance in high-TDS Ca and Na brine drilling fluids.
Is SCL 8054 compatible with other inhibitors?
Absolutely. It can be used alongside traditional inhibitors like Imidazoline/Quat and Coco Quat for enhanced performance.
Why choose SCL 8054 for industrial applications?
It offers versatility, proven protection in diverse conditions, and dependable results, making it a cost-effective solution for corrosion control.